10 inch Spo2 monitor | patient monitor

10 inch Spo2 monitor | patient monitor
Product Detailed
10 inch color TFT display Support 12 channel waves Unique human voice alarm ECG/RESP,NIBP,SPO2,TEMP,dual IBP,CO2 CE, 13485

Multiple-Parameters Patient Monitor

Modul Number: XDH-21L10

10" color TFT display,support 12 channel waves,

9 parameters include:

ECG/RESP,NIBP,SPO2,TEMP,dual IBP, CO2, loC.

Unique human voice alarm

Rich screen larouts:Standard, Big font, Trend table, NIBP trend,ECG full lead, OxyCRG,loC Layout

Powerful storage: maximum 720 hour graphic and tabular trends od all parameters, up to 10000NIBP review, 200 alarm event review, 2 hours of all waveforms

System software can be upgraded through network

XDH-21L10
ECG
1. Lead mode:I,II,III,AVR,AVL,AVF,V
2. Gain:×0.25, ×0.5, ×1, ×2
3. Heart Rate:    Resolution:    Accuracy:15-300bpm (Adult)   15-350bpm (Pediatric/Neonatal)1bpm±1%
4. Bandwidth:Diagnostic:0.05~130HzMonitor:0.5~40HzSurgery:1~20Hz
5. Sweep Speed:12.5mm/s, 25mm/s, 50mm/s
6. Pacemaker rejection:Yes
7. ST measurement Range:    Accuracy:-2.0~+2.0mV±0.02mV or ±10% which is greater
  
SpO2
1. Measure range:0-100%
2. Resolution:1%
3. Accuracy:±2%(70-100%); ±3%(40-69%);unspecified (<40%)
4. Pulse Rate:    Resolution:    Accuracy:20-300bpm1bpm±3bpm
  
NIBP
1. Work Mode:Manual, Automatic, continuous
2. Unit:mmHg, kPa
3. Measure range:                                                Adult:                                                Pediatric:                                                Neonatal:SYS:40-280mmHgDIA:10-220mmHgMEAN:20-240mmHgSYS:40-220mmHgDIA:10-160mmHgMEAN:20-170mmHgSYS:40-135mmHgDIA:10-100mmHgMEAN:20-110mmHg
4. Resolution:1mmHg
5. Accuracy:Maximum Mean error:±5mmHg; Maximum Standard deviation:8mmHg
6. Overpressure Protection:Adult          300mmHgPediatric     240mmHgNeonatal     150mmHg
  
RESP
1. Measure range:Adult          0~120rpm
 Pediatric,Neonatal      0-150rpm
2. Resolution:1rpm
3. Accuracy:±2%
  
TEMP
1. channels:2
2. Measure range:0-50centidegree
3. Resolution:0.1centidegree
4. Accuracy:±0.1(25-45) centidegree, ±2(other)centidegree
  
IBP(Optional)
1. channels:2
2. Measure range:-50~360mmHg
3. Accuracy:±2% or ±1mmHg  which is greater
  
CO2(Optional)
1. Measure range:0%~13%
2. Resolution:1mmHg
3. Accuracy:±2mmHg @ <5.0% CO2 (at ATPS)
4. Resp:3-150rpm
  
IoC(Optional)
EEG sensitivity±475 uV
CMRR:>100dB
Input Impedance>50M ohm
IoC0-100
ESR0-100%
EMG0-100
  
RECORDER (Optional)
1. Width:48mm
2. Speed:25/50mm/s
3. Channels:2
  
  
Standard configuration:ECG, RESP, TEMP, NIBP, SpO2
Optional:dual IBP, CO2, IoC, Recorder, VGA